ART19306 Rev. A 12/09Operator’s Manual Blood Glucose and β-Ketone Monitoring SystemPrecision Xceed Pro, TrueID, TrueMeasure, TrueAccess, PrecisionWeb,
2. Using the Monitor Bar Code Scanner Data Entry Keypad Audible Indicator Data Port Battery Compartment Port Protector Monitor Identification
2-1Questions? Refer to Page 10-10 for Technical Support Instructions.Using the MonitorBar Code ScannerThe bar code scanner enables you to scan the inf
2-2Questions? Refer to Page 10-10 for Technical Support Instructions.On/Off Press this button to turn the monitor on. Each time the monitor is turned
2-3Questions? Refer to Page 10-10 for Technical Support Instructions.Monitor IdentificationEach monitor has a unique serial number listed on the back
3. Patient Test Operating Guidelines for All Samples Collecting Blood Samples How to Obtain a Capillary Blood Sample How to Obtain a Venous Bl
3-1Questions? Refer to Page 10-10 for Technical Support Instructions.This chapter describes the steps to be taken to test patient blood glucose or β-k
3-2Questions? Refer to Page 10-10 for Technical Support Instructions.Collecting Blood Samples How to Obtain a Capillary Blood Sample:Use only fresh wh
3-3Questions? Refer to Page 10-10 for Technical Support Instructions.Patient Test Procedure - GlucoseUse the following procedure to perform a patient
What You See on the Display What You Do Comments3-4Questions? Refer to Page 10-10 for Technical Support Instructions.Press 2 to Conrm Patient ID or 1
What You See on the Display What You Do Comments3-5Questions? Refer to Page 10-10 for Technical Support Instructions.12. If required, scan or manuall
iQuestions? Refer to Page 10-10 for Technical Support Instructions.This Operator's Manual provides basic information about the Precision Xceed Pr
3-6Questions? Refer to Page 10-10 for Technical Support Instructions.What You See on the Display What You Do Comments13. You can select one of the fo
3-7Questions? Refer to Page 10-10 for Technical Support Instructions.Patient Test Procedure - β-KetoneUse the following procedure to perform patient t
4. Control Test Operating Guidelines for Control Solution Testing Control Test Procedure - Glucose Control Test Procedure - β-Ketone
4-1Questions? Refer to Page 10-10 for Technical Support Instructions.This chapter describes the steps for running a control test with control solution
4-2Questions? Refer to Page 10-10 for Technical Support Instructions.Note: The following section illustrates some common settings. Depending on your i
What You See on the Display What You Do Comments4-3Questions? Refer to Page 10-10 for Technical Support Instructions.5. P r e s s Scan to scan the
What You See on the Display What You Do Comments4-4Questions? Refer to Page 10-10 for Technical Support Instructions.9. Wait for the monitor to analy
4-5Questions? Refer to Page 10-10 for Technical Support Instructions.What You See on the Display What You Do Comments1. Repeat steps 1 through 6 from
5. Data Review Data Review for Patient by Operator ID Data Review for Patient by Patient ID Data Review for All Patient Data Data Review for Contr
5-1Questions? Refer to Page 10-10 for Technical Support Instructions.The Precision Xceed Pro Monitor stores the results of up to 2,500 patient tests,
iiQuestions? Refer to Page 10-10 for Technical Support Instructions.10. Troubleshooting ...
5-2Questions? Refer to Page 10-10 for Technical Support Instructions.4. P r e s s Scan to scan the Operator ID bar code or manually enter the Ope
5-3Questions? Refer to Page 10-10 for Technical Support Instructions.Data Review for Patient by Operator IDPlease refer to the beginning of this Data
5-4Questions? Refer to Page 10-10 for Technical Support Instructions.105 mg/dL1. P r e s s 2 to select Patient by PatID. 2. Press Scan to scan th
5-5Questions? Refer to Page 10-10 for Technical Support Instructions.1. P r e s s 3 to select All Patient Data. The monitor will show all patient
5-6Questions? Refer to Page 10-10 for Technical Support Instructions.1. Press 4 to select Control Data.The monitor shows the result of the most recen
5-7Questions? Refer to Page 10-10 for Technical Support Instructions.1. Press 5 to select Proficiency Data. The monitor shows the most recent profici
5-8Questions? Refer to Page 10-10 for Technical Support Instructions.1. Press 6 to select Linearity Data. The monitor shows linearity tests first by
6. Proficiency TestProficiency Test - GlucoseProficiency Test - β-Ketone
6-1Questions? Refer to Page 10-10 for Technical Support Instructions.Proficiency Test - GlucosePlease use the following procedures to perform a profic
What You See on the Display What You Do Comments6-2Questions? Refer to Page 10-10 for Technical Support Instructions.6. P r e s s Scan to scan the
1. Overview Intended Use TrueID, TrueMeasure and TrueAccess Icons and Warnings Conventions System Components
What You See on the Display What You Do Comments6-3Questions? Refer to Page 10-10 for Technical Support Instructions.9. Bring prociency survey speci
6-4Questions? Refer to Page 10-10 for Technical Support Instructions.1. Follow steps 1 through 8 in the last section on the Glucose Proficiency Test.
7. Linearity Test
7-1Questions? Refer to Page 10-10 for Technical Support Instructions.What You See on the Display What You Do CommentsLinearity Test1. P r e s s On/
What You See on the Display What You Do Comments7-2Questions? Refer to Page 10-10 for Technical Support Instructions.5. Select Glucose or β-Ketone Li
What You See on the Display What You Do Comments7-3Questions? Refer to Page 10-10 for Technical Support Instructions.9. P r e s s Scan to scan the
What You See on the Display What You Do Comments7-4Questions? Refer to Page 10-10 for Technical Support Instructions.12. Follow the instructions in t
8. Review Setup Monitor Configuration Review Setup Review Test Setup for All Tests Review Test Setup for Test Type Review Test Setup for Patient
8-1Questions? Refer to Page 10-10 for Technical Support Instructions.Monitor ConfigurationThe Precision Xceed Pro Monitor configuration settings are e
8-2Questions? Refer to Page 10-10 for Technical Support Instructions.Operator IDDecide whether an operator can continue to test (“allow test” or “warn
1-1Questions? Refer to Page 10-10 for Technical Support Instructions.Intended UseThe Precision Xceed Pro Point of Care System for Blood Glucose and β-
8-3Questions? Refer to Page 10-10 for Technical Support Instructions.1. P r e s s On/Off to turn on the monitor.The Abbott logo screen will appear
8-4Questions? Refer to Page 10-10 for Technical Support Instructions.1. Press 1 for Test Setup.2. P r e s s 1 for All Tests to continue to the All
8-5Questions? Refer to Page 10-10 for Technical Support Instructions.1. Press 1 for Test Setup.2. P r e s s 2 for Test Type to continue to the Test
8-6Questions? Refer to Page 10-10 for Technical Support Instructions.1. Press 1 for Test Setup.2. Press 3 for Patient Test to continue to the Patient
8-7Questions? Refer to Page 10-10 for Technical Support Instructions.1. Press 1 for Test Setup.2. Press 4 for Control Test to continue to the Control
What You See on the Display What You Do Comments8-8Questions? Refer to Page 10-10 for Technical Support Instructions.7. P r e s s 1-Next to contin
8-9Questions? Refer to Page 10-10 for Technical Support Instructions.1. Press 1 for Test Setup.2. P r e s s 5 for Security to continue to the Secur
What You See on the Display What You Do Comments8-10Questions? Refer to Page 10-10 for Technical Support Instructions.7. P r e s s 1-Next to contin
8-11Questions? Refer to Page 10-10 for Technical Support Instructions.1. Press On/Off to turn on the monitor.The Abbott logo screen will appear in bl
8-12Questions? Refer to Page 10-10 for Technical Support Instructions.6. P r e s s 1-Next to continue to the System Status Time screen.7. P r e
1-2Questions? Refer to Page 10-10 for Technical Support Instructions. Chapter 1: OverviewIcons and WarningsInformation that is of particular relevance
9. Data Upload Docking Station Mounting Instructions Enabling Data Upload
9-1Questions? Refer to Page 10-10 for Technical Support Instructions.Once the test results have been collected during a prescribed period of time, the
9-2Questions? Refer to Page 10-10 for Technical Support Instructions.Docking Station The Precision Xceed Pro System offers an optional docking station
9-3Questions? Refer to Page 10-10 for Technical Support Instructions.Enabling Data UploadThe docking station has two ports located on the back: an AC
10. Troubleshooting Troubleshooting Patient Test Results Troubleshooting Out-of-Range Control Test Results Troubleshooting Out-of-Range Linearity
10-1Questions? Refer to Page 10-10 for Technical Support Instructions.Troubleshooting Patient Test ResultsThis section describes conditions that can c
10-2Questions? Refer to Page 10-10 for Technical Support Instructions.When You Turn on the Monitor, or During Use:The display is blank.Symptom/Error M
10-3Questions? Refer to Page 10-10 for Technical Support Instructions.When You Turn on the Monitor, or During Use:Symptom/Error Message Explanation Ho
10-4Questions? Refer to Page 10-10 for Technical Support Instructions.When You Turn on the Monitor, or During Use:Symptom/Error Message Explanation Ho
Symptom/Error Message Explanation How To Respond10-5Questions? Refer to Page 10-10 for Technical Support Instructions.The Glucose QC Interval Controls
1-3Questions? Refer to Page 10-10 for Technical Support Instructions.System Components The Precision Xceed Pro Monitor is part of an overall system de
10-6Questions? Refer to Page 10-10 for Technical Support Instructions.Symptom/Error Message Explanation How To RespondDuring Any Test:The bar code jus
10-7Questions? Refer to Page 10-10 for Technical Support Instructions.During Any Test:The Operator ID just entered is not on the list of acceptable O
10-8Questions? Refer to Page 10-10 for Technical Support Instructions.Symptom/Error Message Explanation How To RespondThe test result is below the mea
10-9Questions? Refer to Page 10-10 for Technical Support Instructions.When a Control Test is Selected:When a Linearity Test is Selected:A control solu
10-10Questions? Refer to Page 10-10 for Technical Support Instructions.Technical Support InstructionsAbbott Technical Support contact information is l
10-11Questions? Refer to Page 10-10 for Technical Support Instructions.Contacting Abbott for ServiceAbbott is committed to helping you resolve any pro
10-12Questions? Refer to Page 10-10 for Technical Support Instructions.LATIN AMERICAArgentinaAbbott Laboratorios de Argentina S/AAbbott Diabetes CareB
11. Maintenance Cleaning the Exterior Surface Replacing the Port Protector Battery Life Replacing the Batteries
11-1Questions? Refer to Page 10-10 for Technical Support Instructions.IMPORTANT: Do not allow liquid to enter the monitor. Permanent damage could occu
11-2Questions? Refer to Page 10-10 for Technical Support Instructions.Battery Life The average alkaline battery life is approximately 60 days, based o
1-4Questions? Refer to Page 10-10 for Technical Support Instructions. Chapter 1: OverviewTest StripsPrecision Xceed Pro Test Strips offer the latest a
12. SpecificationsPrecision Xceed Pro MonitorSymbolsBar Code TypesImportant Safety Instructions
12-1Questions? Refer to Page 10-10 for Technical Support Instructions.Precision Xceed Pro MonitorDimensions:Length: 19.7 cm (7.7 in)Width: 7.5 cm (
12-2Questions? Refer to Page 10-10 for Technical Support Instructions.SymbolsThere are special symbols that appear on the Precision Xceed Pro Monitor,
12-3Questions? Refer to Page 10-10 for Technical Support Instructions.Bar Code Types Codabar: Codabar is a self-checking, numeric-only bar code. Codab
12-4Questions? Refer to Page 10-10 for Technical Support Instructions.RSS: RSS is an abbreviation for Reduced Symbology Set, which produces very small
12-5Questions? Refer to Page 10-10 for Technical Support Instructions.Standards Compliancee Precision Xceed Pro System has been evaluated against the
1-5Questions? Refer to Page 10-10 for Technical Support Instructions.Calibration Verification ControlsUse RNA Medical brand Glucose and β-Ketone Calib
Komentarze do niniejszej Instrukcji